Displays the Temperature Spec Window where you can enter Temperature.
One of the following operational constraints needs to be specified
Maximum Tubeskin Temperature
Maximum Delta Temperature
Maximum Tubeskin Temperature - This is the maximum permissible temperature of the tubeskin, along the length of the tube.
Maximum Delta Temperature - This is the temperature difference that exists between the Maximum Tubeskin temperature and the average tubeskin temperature, along the length of the tube.
Note : Given one of the above, the other can be calculated.
These are used as the estimates; sometimes the temperature could exceed the maximum limits for convergence. In such cases, a warning is thrown.
The ambient temperature has to be specified. This is taken as reference temperature for calculations.