Displays the General Spec Window where you can enter data for Gas to Process Heat Transfer Specification, Gas to Wall Heat Transfer Specification and Combustion Gas Thermal Specification. At most only two of the tabs can be selected in each of the groups along with the following constraints.
General rules for selection of Data to be supplied:
General Spec Window requires data to be entered on four fields. Once a total of four data fields are input by the user on the above two sub tabs in accordance with the above rules the requirement of data is complete and the user can move on to the next tab.
At any given time any one of the following two can be selected
Process Outlet temperature
Process Duty
Also from the following two, only one can be selected
Wall Heat Loss
% Firing Duty Lost Through Wall
Subject to the above two rules only two of the following five can be selected
Process Outlet temperature
Process Duty
Wall Heat Loss
% Firing Duty Lost Through Wall
BridgeWall Temperature
"Gas to Process Heat Transfer Specification" SubTab
A minimum of one data field should be selected and no more than two data fields can be selected.
"Gas to Wall Heat Transfer Specification" subtab
A minimum of one data field should be selected and no more than two data fields can be selected.
"Combustion Gas Thermal Specification" subtab
Data entry on this subtab is optional
Related Topics
Fired Heater - Technical Information
Fired Heater - Main Window
Fired Heater - Temperature Spec
Fired Heater - Pressure Spec
Fired Heater - Initial Estimates
Fired Heater - Salient Features
Fired Heater - Limitations
Fired Heater - Design and Assumptions
Fired Heater - Modes of Operation
Fired Heater - Preconditions