Use this window to enter details of the Pressure Drop Options Window where you enter data related to the pressure drop values on the Shell side or Tube side or both. The default value for Scaling factor is one. The Ranges are taken from the Rigorous Heat Exchanger unit Operation.
Pressure Drop Options
Use this window to enter data for tube side and Air side pressure drop options. These data provide s adjustment factors and/or override calculated values for the pressure drops. All the data in this window has default values.
Usage
Tubeside and Airside Pressure Drops
You may enter either a scale factor or a pressure drop for each side of the exchanger.
DP Scale Factor
Enter a value to be applied to the rigorously calculated pressure drop.
DP/Bundle
Enter a value for pressure drop per bundle to override the rigorously calculated pressure drop. The total pressure drop for the entire heat exchanger unit is calculated by multiplying this value by the number of shells in series.
DP/Service
Enter a value for the total pressure drop for the entire heat exchanger unit to override the rigorously calculated pressure drop.
Related Topics
Air Cooled Heat Exchanger - Main Window
Air Cooled Heat Exchanger - Technical Information
Air Cooled Heat Exchanger - Multi Bundle Options
Air Cooled Heat Exchanger - Material Data
Air Cooled Heat Exchanger - Air Side Options
Air Cooled Heat Exchanger - Film Coefficients
Air Cooled Heat Exchanger - Fan Options
Air Cooled Heat Exchanger - Fins Option
Air Cooled Heat Exchanger - Tube Side Options
Air Cooled Heat Exchanger - Specs Options
Air Cooled Heat Exchanger - Print Options
Air Cooled Heat Exchanger - Tube Side Nozzles Options
Air Cooled Heat Exchanger - Design Options