Use this window to enter details of the Design Options Window where you enter data related to Design Mode. This window will be enabled only when Design Mode is selected. The Default values are mentioned in the window.
RANGE:
MIN AREA/BUNDLE - ANY POSITIVE VALUE
MAX AREA/BUNDLE - ANY POSITIVE VALUE
MIN BUNDLE WIDTH - ANY POSITIVE VALUE
MAX BUNDLE WIDTH - ANY POSITIVE VALUE
MIN TUBE PASS - ANY POSITIVE VALUE
MAX TUBE PASS - ANY POSITIVE VALUE
MIN TUBE ROWS - ANY POSITIVE VALUE
MAX TUBE ROWS - ANY POSITIVE VALUE
MIN BAYS IN PARALLEL - ANY POSITIVE VALUE
MAX BAYS IN PARALLEL - ANY POSITIVE VALUE
MIN TUBE LENGTH - ANY POSITIVE VALUE
MAX TUBE LENGTH - ANY POSITIVE VALUE
TUBE LENGTH INCREMENT - ANY POSITIVE VALUE
MIN DP PER UNIT (TUBE) - ANY POSITIVE VALUE
MAX DP PER UNIT (TUBE) - ANY POSITIVE VALUE
MIN DP PER UNIT (AIR) - ANY POSITIVE VALUE
MAX DP PER UNIT (AIR) - ANY POSITIVE VALUE
MIN VELOCITY (TUBE) - ANY POSITIVE VALUE
MAX VELOCITY (TUBE) - ANY POSITIVE VALUE
MIN VELOCITY (AIR) - ANY POSITIVE VALUE
MAX VELOCITY (AIR) - ANY POSITIVE VALUE
Design only. Limits the area per shell. Enter minimum and maximum values. There are no defaults.
Design only. Specifies minimum, maximum, and incremental tube lengths. PRO/II uses the maximum length to initiate the design and reduces the length by the increment specified if the
tubeside pressure drop and velocity specifications cannot be met at the minimum number of passes allowed for the design. The default values are: 24, 40, 2 ft (English input units), or 7.315, 12.2, 0.609 m (Metric and SI input units).
Specifies the upper and lower limit for number of tube passes per bundle. Enter minimum and maximum values. The default is 1,12.
Specifies the minimum and maximum number of tube rows per bundle. Enter minimum and maximum values. The defaults are 2 and 12.
Specifies the minimum and maximum values for pressure drop per bundle. PRO/II averages the lower and upper limits to determine the target pressure drop for the specified
bundle arrangement. The defaults are 5, 15 psi (English), 0.352, 1.055 kg/cm 2 (metric), or 34.47, 103.42 kPa (SI). You cannot enter DPSHELL and DPUNIT together.
Specifies lower and upper limits for tubeside velocity. Enter minimum and maximum values. The default is 0,1000 ft/sec (English), or 0, 304.8 m/s (metric and SI).
Specifies the minimum and maximum width of the bundle. Enter lower and upper limits values in ft (English) or m (metric and SI). The defaults are 5, 12 ft (English) and 1.525, 3.657 m (metric and SI).
Specifies the minimum and maximum airside pressure drop per bundle. Enter lower and upper limits. PRO/II calculates the average between the minimum and maximum values to use as the target pressure drop in obtaining a suitable tube bundle. The defaults are 0.3, 0.7 in. H2O (English) and 7.62, 17.8 mm H2O (metric and SI). You cannot enter DPSHELL and DPUNIT together.
Design only. Specifies the minimum and maximum airside velocities. Enter lower and upper limits in ft/hr (English) or m/s (metric and SI). The defaults are 0.00 & 1000.7 ft/sec (English input units) and 0.0 & 305.01 m/s (metric and SI input units).
Specifies the minimum and maximum number of bundles per bay in parallel. There are no defaults.
Related Topics
Air Cooled Heat Exchanger - Main Window
Air Cooled Heat Exchanger - Technical Information
Air Cooled Heat Exchanger - Multi Bundle Options
Air Cooled Heat Exchanger - Material Data
Air Cooled Heat Exchanger - Air Side Options
Air Cooled Heat Exchanger - Film Coefficients
Air Cooled Heat Exchanger - Fan Options
Air Cooled Heat Exchanger - Fins Option
Air Cooled Heat Exchanger - Tube Side Options
Air Cooled Heat Exchanger - Pressure Drop Options
Air Cooled Heat Exchanger - Specs Options
Air Cooled Heat Exchanger - Print Options
Air Cooled Heat Exchanger - Tube Side Nozzle Options